Grounding dust collection Apply conductive metal tape as shown here . Description. Grounding Kit provides everything you need to ground a dust collection system. My dust collection system is fairly simple, a 2hp collector and a 20 ft hose that gets connected to the machine in use. This will provide a low-resistance path for any stray electricity to follow, preventing it from causing damage or injury. A picture is worth a 1000 words so it may be easier to refer people to the picture. Dec 11, 2011 · I just bought a Grizzly 3hp dust collector. It is not recommended for use near flammable or combustible liquids, gases, or explosive dusts such as gasoline or other fuels, lighter fluids, cleaners/solvents, oil-based paints, natural gas, hydrogen, coal dust, magnesium Jan 26, 2017 · To ground your dust collection piping system, run your wire along or around the pipe throughout the system. Sep 18, 2023 · Proper grounding is key to ensuring that your dust collection system is safe and effective. I also haven’t had any more issues since re routing it up and over and also Ground tool – usually grounding dust collection system is sufficient. Mar 19, 2024 · Though many dust collection systems will not come with a built-in grounding system, these can be added and may even be sold by your dust collection system provider. filter bag. Test continuity between ground at the blower and the duct. Grounding minimizes the risk of fire and improves the system’s performance. All dust collection systems build up static electricity, and if not grounded, that electricity becomes a hazard that could start a fire. Kit includes 50' of 14-gauge bare copper wire, electrical connectors, grounding screws Jul 1, 2013 · Grounding the plastic in a dust collection system is usually to prevent the user from getting zapped from the pipes, in which case the ground wire can be wrapped around the outside of the pipe. Vacuums and Dust collectors For the vacuum itself, you have two options, a shop vac, or a dedicated dust collector. If the tubing is solid, you can insert a screw through the tube wall and run a line of grounding wire along the interior of the wall and around the threads of the screw, and another line outside the tube, again connected to the screw. Jan 6, 2024 · Copper Grounding Wire. Dust collection fittings must be grounded to dissipate static electrical charges. For over thirty years, we've dedicated ourselves to manufacturing the best performing and highest quality dust collection systems for shops of all sizes. C. Grounding can be achieved using a variety of methods, including copper wire, grounding rods, and grounding straps. Until I have the time and money to run duct work through the entire shop I bought a 20 foot flex hose to use when I am running a piece of equipment. Oct 11, 2023 · The collector line is a discontinued ShopVac system but it is attached to the Shopvac through a Dust Deputy cyclone dust collector. Jul 19, 2021 · I am going to be setting up dust collection in my garage and was considering using pvc piping because of its cost and ease of use. Fixing the Problem If you believe any of this is happening to you the appropriate fix will depend on your particular situation. The only problem is that the dust collector is in the shop and if I forget to turn on the ShopVac the 735X produces enough output to blow the top off of the Dust Deputy and that really gets dust all over the garage I know I'm resurrecting an old thread, but for those who come later, I found this video pretty compelling that shows grounding a PVC dust collection system is basically useless because PVC is an insulator (which is why wires are wrapped in PVC), so wrapping the outside of the system is completely useless (because static on the inside won't be grounded due to the insulation) and even putting Feb 22, 2023 · Woodstock W1053 Grounding Kit for Dust Collection Systems https://a. I still haven’t gotten around to grounding it. of stranded copper wire, 5 wire nuts, two grounding screws and ring terminals for grounding two woodworking machines. See full list on diyquickly. I also use it to clean up the machines at the end of the day. W1053 Dust collection systems build up static electricity and if they are not properly grounded the electricity can become a serious hazard that could start a flash fire. Jun 17, 2009 · Pool equipment is this way; you have to run a separate bonding wire back to the ground bus or to a separate rod pounded into the ground. Can I connect my dust hose grounding wire to the unused ground pin on the back of my control box. This grounding kit contains 50' of 14-gauge copper wire, connectors and screws. In this video I go through some static electricity issues I've had, why, and what I'm doing about it. I’ve read to use a bare stranded copper wire, 16AWG, and that antenna wire will work too. Or more. I also covered a couple of things th What is the optimal way to ground a PVC dust collection system? You CANNOT ground a PVC pipe. There are reports of fires that started in a floor-sander bag and in a dust pile under a table saw. Without proper grounding, you run the risk of electrical hazards and static electricity buildup. POWERTEC 70111/70143/70196 -A practical, safe and cost effective dust collection hose -Enhance your existing workshop dust collection and filtration systems -Length: 10' (70111), 20' (70143), 50' (70196) Rated Safe Grounding PVC and Other Dust Collection Myths by Rod Cole I think more has been written on this topic on the various Web woodworking boards than whether Delta, Jet , or Grizzly has the best table saw for the money! More self proclaimed experts post more bizarre theories than at UFO conventions. Filter bags — A spark can be sucked up and land in a dust collection bag. Ran copper wire thru the flex hose, at the ShopBot end I pulled out the hose and wrapped around the hose clamp to secure it, at the dust collector end I put small hole thru the plastic adapter and sealed the hole, and then connected wire to dust collector. All dust collection systems build up static electricity, and if not grounded, that electricity could become a hazard that could start a fire. Otherwise, may want to ground table bed (PRT tools only). The Aerodyne GPC Dust Collector operates differently. unless you dislike the occasional static shock. The worst of all options. Tie the piece of bare copper there. To ground your PVC system, you can use a grounding kit that typically includes a grounding wire, clamps, and connectors. But I don't think the risk is there. This safety accessory is essential to any complete dust collection assortment. Grounding Kit. be/c2sWwWbAayMIn this video, I give a brief talk about grounding a dust co Apr 5, 2022 · I was watching a youtube video from Stumpy Nubs. Oct 24, 2024 · If your dust collection system is not set up with proper grounding these charges will find and disrupt the LongMill controller. I’ve watched several videos of people grounding the these pipes and they all seem to wrap the copper wire around the pipe and drill into it with screws. Dec 10, 2024 · How to ground a dust collector is a crucial safety measure designed to prevent static electricity buildup, which can lead to hazardous sparks and even fires in a workshop environment. The copper grounding wire is an essential component for creating a low resistance path for static electricity to discharge. While up and running, one pound or more of fine dust per minute must be generated with a 500 CFM dust collector to maintain the minimum dust density that might possibly ignite in the duct, or more than two pounds per minute of fine dust with a 1000 CFM DC. Feb 17, 2020 · Many people ask how to ground dust collection piping. I have had issues in the past in marlin mode on my LR3 of the screen going bazirk in the middle of a cut and when i asked about it static in the ungrounded hose was the most common answer. This system as proved the best for me over the past 5 shops. https://youtu. I too, haven't been able to or ever heard of a hobbyist/small shop incident due to not grounding the dust collection. I’ve stressed this numerous times. The other end should extend to the outlet port on the tool, but it doesn't need to connect to anything, except to keep it in place. Oct 10, 2007 · If you do ground the system, you will still get static build-up, but perhaps not as much. Kit includes Jan 3, 2021 · A shed houses the dust collector outside the shop. There have been explosions in industrial-scale dust collection systems. dust is charged (whether the ducts are metal or PVC, grounded or not) and the concentration of dust also con-centrates the space charge due to the dust cloud, making an electrical discharge within the dust cloud a possibility. Proper grounding of a dust collection system involves connecting all components to a common ground. And the dust collector is the vacuum cleaner filtering dust and returning clean air either to the building or Oct 14, 2011 · The 4-Inch Left Spiral PVC Dust Collector Hose by POWERTEC. Placing the dust collector outside the shop brought another benefit. I watched a video about dust collector installation and it suggested running copper wire through the inside of the plastic tubing and then wrapping braided aluminum wire around the outside of the tubing. I show how to ground the cyclone itself as well as the coll This video is a follow up to my video "Dust Collection for Newbies". Dust Collection Hose Grounding Kit Rating Required Select Rating 1 star (worst) 2 stars 3 stars (average) 4 stars 5 stars (best) Name Feb 23, 2011 · ABSOLUTELY UNNECESSARY TO GROUND PVC OR OTHER DUST COLLECTION PIPE. If your concerned about fire worry about your finishing rags and their proper drying. EXPAND THIS SECTION FOR MO The discussion will cover two main angles: the dust hazard analysis perspective and the dust collection design implementation standpoint. This kit contains 50 ft. To answer your question, it is perfectly fine to bare one end of the coiled wire that reinforces the hose and ground it. This kit grounds your system against electrical charge buildup. of 14-gauge bare copper wire, electrical connectors, grounding screws and instructions. (Think of the wire as an antenna rather than as a conductor in a circuit. There is plenty supporting science on the web and magazines on this topic. There are many grounding deniers out there. Grounding your dust collection system is crucial for ensuring the safety of your workers and the efficiency of the system. Find where the ground in the plug wire is landed on the machine. Find many great new & used options and get the best deals for JET 50ft Dust Collection Grounding Kit # JW1053 at the best online prices at eBay! Free shipping for many products! Oct 15, 2019 · Hi all, This is my first post so go easy on me😀. Jul 8, 2023 · Through our research, we learned that static which has formed during dust collection can be removed quickly and efficiently by adding an electrical discharge pathway, or grounding circuit, that starts close to where dust enters the collection container and ends somewhere in the earth, or ground. All dust collection systems should be properly grounded, and In this video I show how to do that. Please do note that a large Dust Collection Grounding Kit Plastic pipe & fittings in your dust collection system should be grounded internally to prevent static discharge that might cause a dust explosion or fire. I also haven’t had any more issues since re routing it up and over and also Oct 3, 2012 · Hi all, I recently purchased the Harbor Freight 2hp dust collector system and plan to do a fairly stationary hook up with 4" PVC duct work. Charge WILL accumulate on both the interior and exterior surface. A plastic or PVC pipe system cannot be adequately grounded. However, as you have just discovered, there is a singular practical reason for doing so. This might smolder for hours before a fire erupts. Dec 13, 2010 · Run a piece of bare copper inside your hose. Follow these steps to ensure safety and efficiency. A shop fire or PVC explosion is a very dangerous situation that will most likely result in loss of property and possibly life. The machine's stock bags filter only particles 20 microns and larger. The ground on the cord will only ground the motor. To prevent build-up of static during dust collection, your kit includes a grounding strap and the hardware to install it. Before assembling the Dust Collector be sure that you have all parts described in the Parts List and Assembly Diagram. 12 gauge will fit right through it. Mar 2, 2014 · Dissipating Static Electricity - Grounding The System - Part 4Use simple and inexpensive materials to ground the PVC ductwork and reduce the build-up of stat Celebrating Three Decades of Dust Collection. In this section, we will outline the steps you need to follow to effectively Sep 26, 2000 · I’m installing a new 1 HP Delta dust collector and need to ground the system. I working on the premise that ‘ground is oxygen. We think it's such an important consideration that we have a dedicated grounding block on the machine just for dust collection systems on our Shapeoko 5 Pro CNC Router. Typical industrial pneumatic systems or fines collection system are metal and solidly grounded. Grounding Wire; Wire Nuts Included Apr 23, 2002 · The Ridgid Whole Shop Dust Collection System is designed for the collection of wood and wood-like material by-products. Presumably you'd want to use stranded wire for flexibility. com Sep 18, 2023 · Proper grounding is key to ensuring that your dust collection system is safe and effective. I’m too lazy to run a grounding wire and terminal to the nearest grounded object (overhead iron gas pipe), or put in a dedicated grounding stake and associated wiring. In its simplest form, an industrial ventilation or dust collection system can be described as similar to a vacuum cleaner. There has never been such an explosion in a home-sized dust collection system, as far as I know. Even plastic ducts can build static to dangerous levels. This gives a place for built-up static electricity to be dispersed. Search "Grounding plastic dust collector piping. The dust pile — A saw blade or a sander can hit a piece of metal and a spark can land in a dust pile. One way to ground your system is to use a grounding wire to connect the metal housing of the collection drum or bag to a ground source, such as a metal pipe or the grounding terminal in your electrical panel. 5 days ago · Introduction To Grounding Dust Collection Systems. This kit includes 50-ft. . For added grounding, attach a self-supplied wire with a ring terminal on one end and a washer tied to the other end when installing one of the bolts. Feb 23, 2017 · Of course dust collector mfg will tell you to ground your system as it protects them. Fifty foot grounding kit simply makes your dust collection system safer by grounding your lines to prevent static. Sep 18, 2023 · Grounding your PVC dust collection system helps prevent static buildup, which can lead to dangerous sparks and even explosions. It should be easy to show a ground connection on the metal duct, unless you have plastic joiners or something like that isolating sections. Run your ground wire on the outside to prevent dust/chip obstructions inside your hoses. The ground plate forces vortex reversal to occur in a much shorter space, eliminating the need for a long, tapered body. You could possibly introduce circulating ground current, or have your ground reference change. Apr 7, 2023 · I see grounding the dust collection hose talked about a lot around the forum. A large system may need more than one kit. I was talking to someone today and they mentioned that the system should be grounded as the air and sawdust moving through the PVC will create a fair amount of static and the possibility for sparking will be high. Complete instructions included. The neutral wires go to neutral bus only because they can create ground loops if connected to the ground bus. Grounding dust collection is very important. Features: 50' of braided 14 gauge copper wire Proper grounding of a dust collection system involves connecting all components to a common ground. Aug 9, 2020 · The frame of your dust collector, and all of your machines, are at ground potential. I tried to be clear on what points I know or strongly Jan 4, 2021 · What's happening everyone! In this video I try to dispel some of the myths around grounding pvc pipe and show that is is not possible as pvc is an insulator! Aug 13, 2008 · 1. Foradustexplosion,twomoreelements(labeled inred)arerequired:dustdispersionatorgreaterthanthe dust’sminimumexplosibleconcentration (thelowestdust note: Your Dust Collector will require complete assembly prior to use. If you're using plastic tubing, there's a potential for static to build up on both the inner and outer surfaces. When looking into how to ground a dust collector hose or system, it is important to refer to the manufacturers’ directions as this will be the best method to ensure grounding is Nov 16, 2015 · Well, large dust collector systems will somegimes run a bare copper wire from one end of thd ductwork to the other, grounding one end, due to (apparently unnecessary) fear of static-ignited dust explosions; you could try domething like that and see if it helps. Also, in very large dust piles, the charge in the pile of dust can give rise to discharges along the surface of the pile. I was at LeeValley tools and saw this display and I took a picture. Bonding and grounding of dust collection systems are c Non-metallic dust collection ducting and fittings should be grounded to the woodworking machinery and the dust collector. Static electricity can be a significant ignition risk for facilities handling combustible dust. Small shops just don't produce enough dust to get into it being a high risk thing IMHO. A sloped spiral inlet directs the dirty gas stream toward a fixed ground plate and hopper of the dust collector. The only problem is I can't find any bare stranded wire in San Diego! Oct 2, 2003 · All dust collection systems build up static electricity and if not grounded, that electricity becomes a hazard that could start a fire. He was presenting a way of grounding dust collection systems. GROUNDING DUST COLLECTION. You can reduce the accumulation of charge by: Running a wire inside the pipe to reduce internal charge buildup. If you feel up to grounding it, go for it, it can't hurt. 1. It is important that you read the entire manual to become familiar with the product BEFORE you use the Dust Collector. Make it come out of a hole in the hose at the dust collector. However it is one of those expanding hoses that "stretches" and then collapses for ease of storage. In our training and system configurations we only use a single point of ground and not multiple points of ground to keep form having a different ground potential, with multiple grounding points “Different Static electricity requires grounding a dust collection system which is why Air Handling Systems pro-vides galvanized metal spiral pipe and fittings and flexible hose with wire helix. Running a wire outside the pipe to reduce external charge buildup. The Big Horn D. Jun 16, 2013 · grounding dust collection Post by milo30 » Sun Jun 16, 2013 3:46 am I sometimes run a dust boot on my shark and usually it goes ok but sometimes, especially cutting mdf it will make it go a little haywire. At joints, you should either provide extra slack wire or install bayonet connectors. The dust collection ductwork is the hose and wand that draws the dust away from the machine creating pollutants. Oct 3, 2012 · Hi all, I recently purchased the Harbor Freight 2hp dust collector system and plan to do a fairly stationary hook up with 4" PVC duct work. PVC Dust Collection Hose with 2 Stainless Steel Hose Clamps for Woodworking and Shop Vacuum, 2-1/2" Dust Collector Hose for Dust Collection Fittings 4. If a dust collector, you are losing almost all your flow through a 12 foot flex hose. 7 out of 5 stars Jan 24, 2024 · To ground the gas plumbing you connect a (usually #4 copper) wire between the (metal) gas pipe after the meter to the house ground (grounding electrode system) whose attachment point might be a fat ground wires between the breaker panel and a ground rod. 2. • Engineering - Complete design of a new or modified dust collection system. A large system may need more than one kit, so it's smart to keep plenty of these on hand. Mar 3, 2014 · At my shop I use PVC for my dust collection and have installed grounding wire warped around the pipe and taken to a single point of ground. Grounding your dust collector requires running a wire along the length of a non-conducting material like PVC or at one end of a conducting material like a metal duct and then Sep 5, 2024 · Steps to Ground Your Dust Collection System. co/d/cU10Ptp As others have said, just wrap the wire around the fitting, then you can connect one end to the chassis screw that Greg Parrish pointed out using one of the crimp-on ring terminals. Feb 10, 2023 · Since reducing friction entails lowering the airflow and hence minimizing dust collection and efficiency, grounding your dust collector is the best way to stop static. We fully guarantee our airflow performance and filtration specifications to provide our customers with a safe, practical, and healthy work Jul 14, 2022 · Does it have a HEPA filter? If not, then it is a chip collector and powered fine particle distributor. This bag should include: Hose Static Strap (1x) Ground Wire Cable Assembly (1x) Stainless Steel M5 Lock Washer (1x) M5 Nylon Locking Nut (1x) POWERTEC 70243V 2-1/2 Inch x 20 ft. Without a grounding source it will discharge through you like dragging your feet on carpet. This How a Ground-Plate Cyclone Dust Collector Works. So, I’ll get straight to it. Mar 30, 2022 · The proper way to ground a woodworking dust collection system for those who think static electricity will make their shop explode. Make sure this is well grounded so you don't build a giant capacitor. I just need to move it from machine to machine. May 9, 2022 · The most common way to electrically ground a dust collection system is to connect the system’s metal components to a grounding rod buried in the ground. • Equipment – Explosion Protection Systems, Spark & Fire Protection, Portable Vacuum Cleaners, Central Vacuum systems & Bonding & Grounding Systems. How Common Are Grounding and Bonding Deficiencies in Dust Collection Systems? I’m finally getting around to grounding my 20' length of dust collector 4" flex hose. It's not the usual "ground it" or "just don't touch it" Jun 23, 2011 · Re: grounding a dust collection system Although not inherently dangerous the static discharge from a plastic (PVC) DC hose is unpleasant. Don’t be one of them. Jan 31, 2010 · Grounding provides a path for this excess charge to flow harmlessly to the earth, which is why dust-collection systems in all commercial shops are required by code to be grounded. Jun 8, 2014 · I had comm issues as soon as I hooked up my DC. This fits around the included hose which is conductive. This is more fine dust than most home shops can generate on a continuous basis. Our grounding kit provides everything you need to ground a dust collection system, including directions for installation. The grounding scheme for your Jul 24, 2023 · Electrical code requires a single ground for your system. Any dust system can build up static electricity. Driving a second ground rod creates the ability to have two ground references, through the dust collection system, and the machines. The kit includes 50 feet of braided 14 gauge copper wire, grounding screws, wire nuts and terminal ends for a complete and easy installation process. Topics include common deficiencies in grounding and bonding, and how to address these issues if identified. ) There is no technical/safety reason that necessitates grounding a hobby-grade dust collection system. The large bags on the left are oversize, 1-micron units; at right, the collector's stock 20-micron bags. The supposed risk of said static build-up is that you may have a dust explosion. Any non metallic flexible connections will have a ground jumper , continuing the ground path. A large system may need more than one kit, so keep plenty of these on hand. The dust and debris rushing through the pipe/hose will induce a static charge. I thought he had some good ideas and if you are having disconnects due to static then give it a watch. This includes the dust collector, ductwork, and all other equipment in the system. It shows how the grounding wire is run with diferent adapters of a DC system. It is crucial in dissipating the electrical charge efficiently to provide a safe and grounded environment for the dust collection system. Oct 28, 2015 · Grounding Dust Collection is Important. Specifications: 50 ft. So your ground on a 115vac plug will work and is simpler. I'm talking about 1/8" hole in the hose. You only need to ground it at one end. Kit includes 50' of 14-gauge bare copper wire, electrical connectors, grounding screws, terminal ends and instructions. A shop-vac collector, like the Fein, Festool, Mirka, Hilti, Bosch, Makita, etc does better. Dec 10, 2002 · Dust Collection Grounding – Metal Tape? Daninvan | Posted in General Discussion on December 10, 2002 09:34am I just built a DC system using 4″ PVC pipe, with ABS Our grounding kit provides everything you need to ground a dust collection system, including directions for installation. Here is part 2 of the dust collection system the grounding. As dust particles are collected, they can generate static charge, especially when moving through ducts and filters. However, an insulator is a very poor conductor of electricity. In reality, the risk is extremely small and close to zero. Learn how to ground a dust collection system to prevent static buildup. • Audits - On-site evaluation of your current dust collection systems. I found the best Find many great new & used options and get the best deals for Woodstock W1053 Grounding Kit for Dust Collection Systems 1 at the best online prices at eBay! Free shipping for many products! Dec 17, 2024 · Connect the ground wire's conductor to the dust collector's metal frame or housing. National Fire Protection Association (NFPA) requires pipes Grounding the Dust Deputy is an optional step recommended for fine dust situations or electronically sensitive applications. Nov 20, 2017 · Fast and simple way to ground PVC dust piping. Static electricity can build up in plastic dust-collection ducting if that energy can’t dissipate via a ground wire. eyibud gixdugz osx qsr dbpp trd ppprddw osvw pzgwd iqfj